[fusion_builder_container hundred_percent=”no” hundred_percent_height=”no” hundred_percent_height_scroll=”no” hundred_percent_height_center_content=”yes” equal_height_columns=”no” menu_anchor=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” status=”published” publish_date=”” class=”” id=”” background_color=”” background_image=”” background_position=”center center” background_repeat=”no-repeat” fade=”no” background_parallax=”none” enable_mobile=”no” parallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” video_preview_image=”” border_size=”” border_color=”” border_style=”solid” margin_top=”” margin_bottom=”” padding_top=”” padding_right=”” padding_bottom=”” padding_left=””][fusion_builder_row][fusion_builder_column type=”1_1″ layout=”1_1″ spacing=”” center_content=”no” link=”” target=”_self” min_height=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_image_id=”” background_position=”left top” background_repeat=”no-repeat” hover_type=”none” border_size=”0″ border_color=”” border_style=”solid” border_position=”all” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”” margin_bottom=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” last=”no”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]

APARTMENT BUILDINGS (APARTMENTS AND FLATS) Bye Laws

Buildings
The following setbacks and basic provisions in the apartments shall be considered: 

  1. Setbacks:
Set Backs Front Side Rear
Apartment/ Flats 40feet

(In case of row of flats with front open from front line.)

60 feet

(In case of row of flats facing each other)

20 feet

(In between end of blocks of apartment or flats either facing each other or Placed as single row from front line.)

20 feet

(At rear as service road for garbage collection and as privacy buffer for apartment or flats placed back to back.)

  1. Parking:

Minimum of one car per apartment shall be provided along the road either in open or under sheds or in the basement of the building.

  1. Staircase:

Apartments not exceeding eight in numbers shall be provided with minimum of one stair case with a minimum width of four feet.

  1. Water Tank:

An overhead water tank of minimum twenty five hundred gallons for a group of eight flats. In addition, underground water tank for minimum of twenty five hundred gallons of water also be provided.

  1. Solid Waste Management:

Garbage disposal chute accessible to eight number flats and a receptor shall be provided at ground or basement level.

  1. Septic Tank:

In case of unavailability of sewerage a septic tank and a soakage pit shall be provided.

  1. Fire Precautions:

Minimum of two numbers of firefighting extinguishers shall be provided at each floor landing area.

  1. Lighting:

Lighting conductor for a group of eight apartments needs to be provided.

  1. Emergency Exit:

Provision of emergency exit is mandatory.

  1. Provision of Ramp:

In apartments, a ramp of minimum six feet width and having maximum gradient of 1:12 shall be provided. In case of non-provisions of lifts, each floor shall be accessible through this ramp.

The covered area of the top story of residential building shall not exceed the covered area of ground floor

Note: For public building only according to site topographical conditions amendments may be allowed w.r.t. terraces, no., or floors.